These properties give graphene a great affinity for carbon-based aromatic cyclic compounds. ![]() In the field of analytical chemistry, it has found significant applications as a sorbent to be used in solid phase extraction, since G has a huge surface area and can make π- π interactions due to electron delocalization. Since its discovery, graphene (G) has gained the interest of the entire scientific community due to its possible applications in the production of new materials with clearly superior performance. Moreover, from the results obtained it is evident that, despite the use of some recycled materials, the performances obtained were comparable or even superior to the methods reported in the literature. We report herein on some of the outstanding advantages of using carbon-based sorbent, such as lower toxicity, scalability, improved absorption capacity, target selectivity and stability in acidic medium. Samples were extracted using 25 mg of sorbent at pH 5 and desorbed in 5 min using methanol. Several experiments were carried out to evaluate the influence of different parameters involving the dispersive magnetic solid phase extraction of these analytes. A gradient elution was used for the separation of the analytes, while for the quantitative analysis each analyte was determined at its maximum wavelength. A UHPLC-PDA method was developed for the simultaneous determination of antibiotics from different drug families (carbapenems, fluoroquinolones, β-lactams) using a 120 SB-C 18 poroshell column (50 × 2.1 mm I.D., 2.7 um particle size) and a mobile phase consisting of 10 mM acetate buffer at pH 5 (Line A) and acetonitrile (Line B) both containing 0.1% of triethylamine. Characterizations were carried out to evaluate the composition (Raman, XRD and EDX) and the morphological structure (SEM) of the material. The precursor underwent a carbothermal reduction to promote the formation of paramagnetic phases useful for the recovery of the sorbent during the analysis, and to disperse and fix graphene and the iron oxide in a durable way throughout the cellulose structure. Phillips is aregistered trademark of Phillips Screw Co.All other trademarks are the sole property of their respective owners.Copyright © 2007 Waters Corporation.In this work, a sorbent was prepared from wastepaper samples enriched with iron oxide particles and graphene oxide and used in the solid phase extraction of antibiotics. PEEK tubing is a registered trademark of Victrex Corporation. AACQUITY UPLC and Waters are registered trademarks, and eCord is a trademark of WatersCorporation. Thus, in the 0°, “home”, position,the tray is directly above the sample manager and below the optical detector,and in the 180°, “away”, position, you can plumb the HT column heater into amass spectrometer (located on the system’s right).71500148606, Rev. The column rests in aU-shaped tray, which swivels outward to any position between 0° and 180°and can receive the column from either side. The HT column heater is an assembly thatfits on top of the sample manager and contains the column stabilizerassembly, the optional column in-line filter unit, and a column.The HT column heater’s front compartment can accommodate any WatersACQUITY column up to 4.6 mm ID and 150 mm long. ACQUITY UPLC HT Column Heater InstructionsNote: This document is an addendum to Revision C of the ACQUITY UPLCSystem Operator’s Guide.Contents:TopicPageOverview 1Connecting the cable 4Installing the column stabilizer assembly 5Installing the column in-line filter 9Installing the column 10Installing the column in an MS system 13Maintenance 13Troubleshooting 19Specifications 20OverviewWhen installed on Waters ® ACQUITY UPLC ® Systems, the Waters ACQUITYUPLC High Temperature (HT) Column Heater maintains one column at atemperature up to 90 ✬ (194 ✯).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |